September 07, 2010
IAFF Local Newswire
Join the Newswire!
Updated: Sep. 06 (23:06)
Website and Email access
Pierce County Professional Fire Fighters
09.06.10
Fire Prevention News
IAFF Local F150
09.06.10
General President Schaitberger's State of the Union Address
Albuquerque Area Fire Fighters
09.06.10
Website Update
Scranton Firefighters IAFF Local # 60
09.06.10
Blue Mass
IAFF Local 21
09.06.10
5K RUN/WALK RACE
Fort Drum Firefighters IAFF Local F-105
09.06.10
Fire Safety

BC Fire Code Requirements for Smoke Alarms
Updated On: Aug 27, 2010 (22:51:00)


BC Fire Code Requirements for Smoke Alarms

Smoke Alarms

On March 25, 2010, Minister of Housing Rich Coleman announced new BC Fire Code requirements related to smoke alarms to increase public safety and more closely harmonize with the National Fire Code of Canada.

 

Smoke alarms are cost effective devices that can alert occupants of fire at its early stages, which saves lives and prevents injuries. Smoke alarm requirements were introduced into the BC Building Code in 1979, and have been mandatory in all dwellings and sleeping accommodation rooms (i.e. hotels, motels) since then. BC’s building code requirements are the same as those found in the model National Building Code of Canada. However, the requirements for smoke alarms in the BC Fire Code differ from those in the National Fire Code of Canada in the scope of application. Until now, the BC Fire Code required smoke alarms in all existing hotels and public buildings, but did not require them in all existing dwelling units, such as private homes. Improving public safety by extending the BC Fire Code smoke alarm requirements to private dwellings, including those constructed before March 31,1979, will more closely harmonize the BC Fire Code with the National Fire Code of Canada.

 

The National Fire Code allows for battery-operated smoke alarms. BC will allow battery operated smoke alarms in limited circumstances. Some battery-operated smoke alarms may be less reliable than alarms which are hard wired to a building’s electrical system because they require occupant maintenance and are more easily disabled intentionally or inadvertently. However, the significant cost of installing smoke alarms integrated with a building’s electrical system is likely to discourage their installation in older buildings. The change permits battery operated smoke alarms in those dwelling units constructed prior to the BC Building Code’s mandatory requirement for their installation in dwelling units built before March 31, 1979. Battery operated smoke alarms will also be permitted in buildings that are not connected to electrical power.

 

Revisions to Article 2.1.3.3 of the British Columbia Fire Code

  1. Smoke alarms conforming to CAN/ULC-S531, “Smoke Alarms,” shall be provided in all hotels and public buildings as defined in the Act, where required by and in conformance with the British Columbia Building Code installed in each dwelling unit and, except for care or detention occupancies required to have a fire alarm system, in each sleeping room not within a dwelling unit.
  2. Smoke alarms may be battery operated where permitted by the authority having jurisdiction within dwelling units shall be installed between each sleeping area and the remainder of the dwelling unit, and where the sleeping areas are served by hallways, the smoke alarms shall be installed in the hallways.
  3. Smoke alarms shall be installed in conformance with CAN/ULC S-553, "Installation of Smoke Alarms".
  4. Smoke alarms are permitted to be battery operated in
       a) a dwelling unit constructed before March 31, 1979, or
       b) a building which is not supplied with electrical power.

The changes to the BC Fire Code will require an amendment to the BC Building Code, Division A, Clause 1.1.1.1.(1)(k) to avoid a conflict between the two codes.

Amend

Division A, 1.1.1.1. Application of this Code
1) This Code applies to any one or more of the following
   
k) except as permitted by the British Columbia Fire Code Regulation, the installation, replacement, or alteration of materials or equipment regulated by this Code.

 

The new requirements in the BC Fire Code come into effect on May 1, 2010. Owners of dwelling units built before March 31, 1979 are required to have smoke alarms installed in accordance with the new requirements by that date.

The following information is available:

  • Home Escape Planning (Updated: Jul 14, 2006 21:53:00)
  • Facts about Smoke Alarms (Updated: Nov 20, 2008 22:47:00)


  • Page Last Updated: Aug 27, 2010 (22:51:00)
    Member Login
    Username:

    Password:


    Not registered yet?
    Click Here to sign-up.

    Forgot Your Login?
    <<  September 2010  >>
    S M T W T F S
    1 2 3 4
    5 6 7 8 9 10 11
    12 13 14 15 16 17 18
    19 20 21 22 23 24 25
    26 27 28 29 30
    Important Links
    IAFF
    IAFF Health, Safety and Medicine
    IAFF Fit to Survive
    Coquitlam extranet/email
    IAFF 6th District
    BCPFFA
    BCPFF Burn Fund
    Mesothelioma cancer
    Work Safe BC
    NIOSH FF Fatality Investigation Reports
    National Fire Fighter Near-Miss Reporting System
    Burnaby Firefighters
    Vancouver Firefighters
    Surrey firefighters
    Richmond Firefighters
    National Fallen Firefighters Memorial
    Toronto Firefighters
    Edmonton Firefighters
    Winnipeg Firefighters
    Ottawa firefighters
    Employee and Family Assistance Group
    Firefighter Cancer Support Network
    Firefighter Close Calls.com
    World Police & Fire Games 2009
    NFPA
    City of Coquitlam
    Firehouse.com
    Fire Engineering
    Canadian fallen firefighters foundation
    UBC Firefighter Heart Disease Study
    Canadian IAFF Locals Online
    US Fire Administration
    Everyone Goes Home - Firefighter Life Safety Initiatives
    Google
    IAFF Headlines:
    (From IAFF.org)

    HTTP/1.1 New Session Failed


    >>More Headlines
    Visit Unions-America.com!
     Top of Page © Copyright 2010, International Association of Firefighters Local 1782, All Rights Reserved.
    Powered By UnionActive™
    Hide the Right Hand Column